10. Appendix
(5) Braking resistor RBR2 (standard type)
■
Dimensions (mm)
■
Circuit diagram
RB
P
2
1
■
Connection diagram
(+)
RB
P1
RB 2
Robot driver
Alarm contact
(Normally closed)
Normally ON
Braking resistor
Model No.
Dimensions (mm)
Mass (kg)
L1 L2 L3 H1 H2 W T
KBH-M5850-10 310 295 160 67 12 64 1.6 0.97
Model No.
Rated
wattage
Resistance
Allowable braking ratio
(%ED)
Allowable continuous
braking time
KBH-M5850-10
200W 100
Ω
7.5% (3%)* 30 sec.
Error detection
function
Internal thermal relay (contact capacity, AC 240V, 2A max, Normally ON
(b-contact), internal thermal fuse (unrecoverable)
* : Value in ( ) indicates the allowable braking ratio for 400V class.
Note 1: Thermal relay and fuse are built into the braking resistor.
Note 2: Internal thermal fuse prevents abnormal heat generation which may occur
due to misoperation (unrecoverable).
Note 3: An appropriate safety circuit is configured so that the main power of the
robot driver is turned off if the thermal relay is tripped (an alarm occurs).