5-25
5
Functions
5. Functions
5.7 Smoothing function
(1) Position command filter
The command pulse rate may cause vibrations when used in combination with a
low-rigidity machine. To prevent this vibration, a filter is added to the position
command so that commands can be changed smoothly.
The filter time constant can be set by parameter (Fd-36). Setting the parameter to 0
disables this function.
Parameter Function name Description
Default
setting
Fd-36
Position command
filter time constant
Inserting a filter makes the
position command run smoothly.
0 to 60000ms, 0 = Invalid
0
This function is only valid during position control. The control block is shown below.
+
Position
command
Position
control
Speed
command
Current position
1+Tds
1
Inserting a filter makes the position command run smoothly as shown in the figure
below and vibration can be prevented.
Before filter
insertion
After filter
insertion
Note 1: In position control mode, always set Fd-36 to 0 during unlimited feed in
one way direction, or during synchronous operation of units such as the
conveyor in one way direction. Unless Fd-36 is set to 0, a position
deviation error (E83) will occur.