Installation and wiring
3. Installation and wiring
Position command pulse timing chart
Pulse train signal form
Pulse train input timing
(1) Pulse train
command
When FA-11 = P-S (Movement direction is reversed if FA-11 = -P-S.)
See note below.
t
1
t
2
T
t
0
t
S4
t
S2
t
4
t
S3
t
3
t
S1
"1"
"0"
"1"
"0"
FWD signal
Logic
REV signal
PLS signal
SIG signal
(2) FWD/REV pulse When F
A-11 = F-r (Movement direction is reversed if FA-11 = r-F.)
See note below.
t
1
t
2
T
t
0
t
S0
"1"
"0"
"1"
"0"
FWD signal REV signal
PLS signal
SIG signal
(3)
Phase difference
2-phase pulse
* In the case of
phase difference
2-phase pulse,
the count is
multiplied by 4.
When FA-11 = A-b (Movement direction is reversed if FA-11 = b-A.)
See note below.
t
1
t
2
T
t
0
t
6
t
5
"1"
"0"
"1"
"0"
FWD signal REV signal
PLS signal
(Phase A)
SIG signal
(Phase B)
Note:
When at logic 1, the pulse train input current direction is PLSP
PLSN, SIGP
SIGN.
Position command pulse timing values
Pulse train signal form
(See above)
Line driver signal
(1), (2) above (3) above
Timing
values
Rise time : t
1
, t
3
0.1μs or less 0.1μs or less
Fall time : t
2
, t
4
0.1μs or less 0.1μs or less
Switching time : t
S0
, t
S1
, t
S2
, t
S3
, t
S4
3μs or more
Phase difference : t
5
, t
6
Pulse width : (t
0
/T)×100 50±10% 50±10%
Maximum pulse rate (frequency) 2M (pulses/s) 500k (pulses/s)